Global Supplier of Advanced Lightweight Materials
Technical Support +86 531 8882 1234 info@example.com EN

A1 Fireproof Thermal Insulation Material

Non-Combustible Inorganic Rigid Insulation for Building, Industrial, High-Temperature, and Cryogenic Systems

Ocean Elite A1 Fireproof Thermal Insulation Material is an inorganic rigid insulation material designed for fireproofing, thermal insulation, cold insulation, and energy-saving applications. With Class A1 fire rating, low thermal conductivity, controlled bulk density, and stable performance under demanding service conditions, it is suitable for buildings, roofs, walls, steel structures, pipelines, industrial equipment, LNG systems, and cryogenic insulation projects.

A1 Non-Combustible

Smoke-Free Inorganic Material

Thermal & Cold Insulation

For Buildings & Industrial Systems

Energy-Saving Insulation Use

Ulite Series Options

Ulite-1510, Ulite-2010, Ulite-2510, Ulite-3010, and Ulite-3810 are available for different density, strength, and insulation requirements.

Standard Panel Reference

Standard dimension is 300 × 300 × 25 mm with ±1 mm tolerance, supporting easier project planning and installation reference.

Density & Strength Matching

Bulk density ranges from 0.09±0.02 to 0.23±0.02 g/cm³, while compressive strength ranges from ≥0.7 MPa to ≥2.7 MPa by grade.

Thermal Conductivity Data

Thermal conductivity ranges from 0.040±0.03 to 0.068±0.03 W/m·K at 23°C, helping engineers compare insulation performance by grade.

Project Selection Support

Ocean Elite can support grade comparison, sample evaluation, and project-based recommendations for building, industrial, high-temperature, and cryogenic insulation applications.

High-Performance A1 Fireproof Thermal Insulation Material from Ocean Elite

Ocean Elite A1 Fireproof Thermal Insulation Material is an inorganic rigid material developed for projects that require non-combustibility, smoke-free performance, thermal insulation, cold insulation, and energy-saving capability. It is designed for building and industrial engineering applications where fire rating, thermal conductivity, density, temperature resistance, and installation reliability must be evaluated together.

The material is available in multiple Ulite series grades, including Ulite-1510, Ulite-2010, Ulite-2510, Ulite-3010, and Ulite-3810. These grades provide different bulk density, compressive strength, and thermal conductivity options, allowing engineers to balance lightweight insulation, local load-bearing performance, and project-specific thermal protection requirements.

This material is suitable for high-rise building insulation, roof insulation, steel structure fireproofing, industrial and civil building insulation, high-temperature industrial pipeline and equipment insulation, cold storage, LNG pipelines, cryogenic equipment, and special industrial thermal protection systems.

  • Class A1 non-combustible inorganic rigid material
  • White appearance with no cracks, no large pores, and no powder loss
  • Standard panel dimension of 300 × 300 × 25 mm with ±1 mm tolerance
  • Bulk density range from 0.09±0.02 to 0.23±0.02 g/cm³
  • Compressive strength from ≥0.7 MPa to ≥2.7 MPa by grade
  • Thermal conductivity from 0.040±0.03 to 0.068±0.03 W/m·K at 23°C
  • Operating temperature range from -197°C to 700°C
  • Limit temperature below 750°C
  • Average sound insulation of 40±3 dB at 17.25 kg/m²

A1 Fireproof Thermal Insulation Material Performance Summary

The following performance summary is based on the A1 Fireproof Thermal Insulation Material R1 technical data. It helps engineers compare fire rating, density, compressive strength, water absorption, thermal conductivity, operating temperature, and sound insulation performance before selecting the right grade.

Characteristic DimensionCore ParametersEngineering Meaning
Product SeriesUlite-1510, Ulite-2010, Ulite-2510, Ulite-3010, Ulite-3810Provides different density, strength, and thermal conductivity options for project-based selection.
Appearance QualityNo cracks, no large pores, no powder loss, whiteSupports stable appearance and basic material integrity for engineering use.
Dimension300 × 300 × 25 mm / ±1 mm toleranceProvides standard panel size reference for installation and project planning.
Bulk Density0.09±0.02 to 0.23±0.02 g/cm³Affects insulation weight, layer design, load control, and thermal performance.
Compressive Strength≥0.7 to ≥2.7 MPaHelps evaluate local pressure-bearing capacity and installation reliability.
Water Absorption1.4%Helps assess moisture-related performance during application.
Thermal Conductivity0.040±0.03 to 0.068±0.03 W/m·K @23°CDetermines heat transfer control and insulation efficiency.
Fire RatingClass A1Indicates non-combustible fireproof performance for building and industrial applications.
Operating Temperature Range-197°C / 700°CSupports low-temperature, standard, and high-temperature insulation environments.
Limit Temperature<750°CHelps define upper temperature safety reference for engineering use.
Average Sound Insulation40±3 dB @17.25 kg/m²Adds acoustic insulation value for building and engineering applications.

Engineering Note:
Do not select this material only by density or thickness. A safer specification should compare fire rating, thermal conductivity, compressive strength, operating temperature, water absorption, installation method, and final project environment together.

A1 Fireproof Thermal Insulation Material Ulite Series Technical Parameters

Ocean Elite A1 Fireproof Thermal Insulation Material is available in five Ulite series grades. Each grade provides a different combination of bulk density, compressive strength, thermal conductivity, combustion heat, and mass loss rate. Engineers can use this table as the main technical reference before sample testing or project specification.

Technical ItemUlite-1510Ulite-2010Ulite-2510Ulite-3010Ulite-3810
Appearance QualityNo cracks, no large pores, no powder loss, whiteNo cracks, no large pores, no powder loss, whiteNo cracks, no large pores, no powder loss, whiteNo cracks, no large pores, no powder loss, whiteNo cracks, no large pores, no powder loss, white
Dimension L/W/H / Tolerance300/300/25 mm / ±1300/300/25 mm / ±1300/300/25 mm / ±1300/300/25 mm / ±1300/300/25 mm / ±1
Bulk Density0.09±0.02 g/cm³0.11±0.02 g/cm³0.15±0.02 g/cm³0.17±0.02 g/cm³0.23±0.02 g/cm³
Compressive Strength ≥0.7 MPa1 MPa1.7 MPa2.4 MPa2.7 MPa
Water Absorption1.4%1.4%1.4%1.4%1.4%
Thermal Conductivity @23°C0.040±0.03 W/m·K0.043±0.03 W/m·K0.052±0.03 W/m·K0.058±0.03 W/m·K0.068±0.03 W/m·K
Fire RatingClass A1Class A1Class A1Class A1Class A1
Operating Temperature Range-197°C / 700°C-197°C / 700°C-197°C / 700°C-197°C / 700°C-197°C / 700°C
Limit Temperature<750°C<750°C<750°C<750°C<750°C
Combustion Heat ≤1 MJ/kg0.8 MJ/kg0.6 MJ/kg0.5 MJ/kg0.4 MJ/kg
Mass Loss Rate ≤ @750°C0.030.020.0180.0151
Average Sound Insulation40±3 dB @17.25 kg/m²40±3 dB @17.25 kg/m²40±3 dB @17.25 kg/m²40±3 dB @17.25 kg/m²40±3 dB @17.25 kg/m²

Selection Note:
Ulite-1510 is better suited for lightweight insulation requirements, while higher-density grades such as Ulite-3010 and Ulite-3810 provide stronger compressive strength for applications where local pressure resistance, installation stability, or structural support is more important.

A1 Fireproof Thermal Insulation Material Grade Selection Guide

A1 thermal insulation material selection should be based on project environment, fire safety requirement, thermal conductivity target, bulk density, compressive strength, operating temperature, and installation structure. Different Ulite grades should not be treated as identical products.

Selection RequirementRecommended DirectionWhy It Matters
Lightweight insulation layerConsider lower-density grades such as Ulite-1510 or Ulite-2010Helps reduce system weight while maintaining basic insulation performance.
Stronger local compression resistanceConsider higher-density grades such as Ulite-3010 or Ulite-3810Improves pressure-bearing capability and installation stability.
Better thermal insulation priorityCompare thermal conductivity values from 0.040±0.03 to 0.068±0.03 W/m·KLower thermal conductivity supports better heat transfer reduction.
Building fireproof insulationUse Class A1 rated material with suitable thickness and installation methodHelps meet non-combustible fireproofing requirements.
High-temperature equipment protectionCheck operating temperature range and limit temperatureHelps avoid material mismatch under long-term thermal exposure.
Cryogenic or cold insulation useCheck low-temperature stability and installation continuityHelps reduce cold loss, condensation risk, and thermal bridge issues.

Note:
Final selection should be verified through sample testing and installation simulation, especially for large building projects, industrial equipment, high-temperature pipelines, LNG systems, and cryogenic insulation projects.

 

How to Choose the Right A1 Fireproof Thermal Insulation Material?

Select the right Ulite grade based on thermal conductivity, bulk density, compressive strength, fire rating, operating temperature, installation structure, and project environment. Choosing only by thickness or density may lead to heat loss, poor load performance, installation mismatch, or long-term durability issues.

Lower Density Requirement

Higher Compressive Strength

Lower Thermal Conductivity

High / Low Temperature Application

Key Selection Factors for A1 Fireproof Thermal Insulation Material

Bulk Density

Bulk density ranges from 0.09±0.02 to 0.23±0.02 g/cm³. Lower-density grades help reduce system weight, while higher-density grades usually provide stronger compressive performance.

Compressive Strength

Compressive strength ranges from ≥0.7 MPa to ≥2.7 MPa by grade. It should be considered when the material is used in areas requiring local pressure resistance, panel stability, or installation reliability.

Thermal Conductivity

Thermal conductivity ranges from 0.040±0.03 to 0.068±0.03 W/m·K at 23°C. This value directly affects insulation efficiency and heat transfer reduction.

Fire Rating

All listed Ulite grades are Class A1 fire-rated. This makes the material suitable for applications where non-combustibility and fireproof insulation performance are required.

Operating Temperature

The operating temperature range is -197°C to 700°C, with a limit temperature below 750°C. This makes the material suitable for low-temperature insulation, standard building insulation, and high-temperature industrial applications.

Application Matching

Material thickness and installation methods can be adjusted according to the specific application scenario to balance insulation perform.

High-Rise Building Insulation

Improves building insulation and fire safety while helping reduce HVAC energy consumption and wall load.

Best-fit use: High-rise buildings, public buildings, and fire-sensitive wall insulation systems.

Industrial / Civil Building Roof Insulation

Helps reduce roof heat transfer, minimize thermal bridge effects, and improve long-term building energy performance.

Best-fit use: Industrial roofs, civil building roofs, and energy-saving roof insulation systems.

High-Temperature Industrial Pipeline / Equipment Insulation

Provides thermal insulation and fire protection for pipelines and equipment working under continuous high-temperature conditions.

Best-fit use: High-temperature pipelines, boilers, industrial equipment, and chemical plant insulation.

Cryogenic Insulation / Cold-Chain Systems

Helps suppress thermal bridging, condensation, and cooling loss in low-temperature insulation systems.

Best-fit use: Cold storage, LNG pipelines, cryogenic equipment, and cold-chain engineering projects.

A1 Fireproof Thermal Insulation Material Sourcing Do’s and Don’ts

Recommended Sourcing Practices

✅Confirm the required fire rating and project application before material selection.

✅ Compare bulk density, compressive strength, and thermal conductivity together.

✅ Check operating temperature range and limit temperature before using the material in high-temperature or cryogenic systems.

✅ Select material thickness according to target thermal resistance and installation structure.

✅ Request technical data, sample support, installation guidance, and project documentation before bulk order.

Common Sourcing Mistakes

❌ Choosing only by the lowest density without checking compressive strength.

❌ Using one material grade across different building, roof, pipeline, and industrial equipment conditions.

❌ Ignoring thermal conductivity differences between Ulite grades.

❌ Skipping installation simulation before large-scale project use.

❌ Selecting insulation material without checking fire rating, operating temperature, and long-term durability requirements.

Customization & Technical Support

Ocean Elite can support buyers and engineers with application-based A1 Fireproof Thermal Insulation Material selection. The goal is to help match the right Ulite grade, density, compressive strength, thermal conductivity, service temperature, thickness, and installation method before large-scale project use.

  • Ulite grade comparison
  • Bulk density and thickness selection
  • Thermal conductivity matching
  • Compressive strength requirement review
  • Class A1 fireproof insulation support
  • High-temperature application selection
  • Cryogenic insulation application support
  • Building roof and wall insulation support
  • Industrial pipeline and equipment insulation support
  • Technical documentation and sample support

Quality Testing & Documentation

Ocean Elite focuses on stable A1 Fireproof Thermal Insulation Material performance for building insulation, roof insulation, industrial fire protection, high-temperature equipment insulation, and cryogenic systems. Quality control should focus on appearance quality, dimensional tolerance, bulk density, compressive strength, water absorption, thermal conductivity, fire rating, operating temperature, and batch consistency.

  • Appearance quality inspection: no cracks, no large pores, no powder loss, white appearance
  • Standard dimension verification: 300 × 300 × 25 mm with ±1 mm tolerance
  • Bulk density inspection from 0.09±0.02 to 0.23±0.02 g/cm³ by grade
  • Compressive strength testing from ≥0.7 MPa to ≥2.7 MPa by Ulite series
  • Water absorption verification
  • Thermal conductivity testing at 23°C
  • Class A1 fire rating verification
  • Operating temperature and limit temperature review
  • Combustion heat and mass loss rate reference
  • Average sound insulation data review

 

Quality control is not just a document attached after production. It is the key step that helps you confirm whether the selected Ulite grade can match your real project environment, installation structure, insulation target, fire safety requirement, and long-term service conditions.

Before bulk order, you should confirm the required Ulite grade, density, thickness, compressive strength, thermal conductivity, application temperature, installation method, and testing documentation. This helps reduce the risk of choosing a material that looks suitable on paper but performs poorly in real construction or industrial use.

Frequently Asked Questions

1.What is A1 Fireproof Thermal Insulation Material?
A1 Fireproof Thermal Insulation Material is an inorganic rigid insulation material with Class A1 fire rating, low thermal conductivity, controlled bulk density, and stable performance for building and industrial insulation applications.

2.What Ulite series grades are available?
The available Ulite series grades include Ulite-1510, Ulite-2010, Ulite-2510, Ulite-3010, and Ulite-3810.

3.What is the standard dimension of the material?
The standard dimension is 300/300/25 mm with a tolerance of ±1 mm.

4.What is the bulk density range?
The bulk density ranges from 0.09±0.02 g/cm³ to 0.23±0.02 g/cm³ depending on the selected Ulite grade.

5.What is the compressive strength range?
The compressive strength ranges from ≥0.7 MPa to ≥2.7 MPa depending on the selected grade.

6.What is the thermal conductivity range?
The thermal conductivity ranges from 0.040±0.03 W/m·K to 0.068±0.03 W/m·K at 23°C.

7.What temperature range can the material support?
The operating temperature range is -197°C to 700°C, and the limit temperature is below 750°C.

8.Can Ocean Elite support buyers looking for an A1 fireproof thermal insulation material supplier in China?
Yes. Ocean Elite can support technical buyers with Ulite grade comparison, sample support, technical data, and project-based recommendations for building, industrial, high-temperature, and cryogenic insulation applications.